v3.4 05/03/2026

Bug Fixes:

o Fixed an issue where the Print Preview window was missing text on the right-hand side

o Online Automatic Updates system

  • Requires manual re-installation to Loop Calculator 3 v3.4 or later

New Features:

o Added mode support for ‘55001-845APO XP95 Zone Monitor Module’ with selectable EoL resistor values

Product Changes:

o Added: Intelligent Open-Area AV VADs

  • SA5501-500APO Intelligent Open-Area VAD Cat. W – White Body (White Flash) (W-3.1-10)
  • SA5501-501APO Intelligent Open-Area VAD Cat. W – White Body (Red Flash) (W-3.1-9)
  • SA5501-550APO Intelligent Open-Area Sounder VAD Cat. W – White Body (White Flash) (W-3.1-10)
  • SA5501-551APO Intelligent Open-Area Sounder VAD Cat. W – White Body (Red Flash) (W-3.1-9)
  • SA5500-550APO Intelligent Open-Area Sounder VAD Cat. W – Red Body (White Flash) (W-3.1-10)
  • SA5500-551APO Intelligent Open-Area Sounder VAD Cat. W – Red Body (Red Flash) (W-3.1-9)

o Added: Zone Monitor Module – Single Device

  • 55000-815APO XP95 Zone Monitor Module- Single Device – Iso

o Added: Zone Monitor Module

  • 55001-845APO XP95 Zone Monitor Module

Panel Changes:

o Added: Advanced Smoke Go

  • SC-5101A
  • SC-5201A
  • SC-5401A
  • SC-5802A

o Whitelisted: Advanced MX Pro 5 with CoreProtocol

  • MX-5101A
  • MX-5201A
  • MX-5401A
  • MX-5801A

o Corrected Item Codes:

  • MX 5100, now MX-5101
  • MX 5200, now MX-5201
  • MX 5400, now MX-5401
  • MX 5800, now MX-5802

v3.2 20/03/2025

What’s New:

o New Product Additions:

  • Soteria & Discovery AV Base range
  • Intelligent Open-Area AV range
  • AV Control Modules (Faceplate + DIN Rail versions)
  • XP95 Three Channel I/O Module
  • Soteria Multi-Sensor Detector (Optical/Heat) – Black

o New Panel Additions:

  • Eurotech Toccare Panels
  • SAFETEC ST-AL1
  • Morley-IAS Panels
  • MTech MA1

Feature Additions

o Added splash screen when opening the app

o Reduced Windows security prompts (UAC) when installing (added code signing)

o Algorithm

  • Revised cable length calculations for non-fireproof cable, which will extend maximum cable run calculations in some situations

Bug Fixes:

o Default Interface LED setting changed from Disabled to Enabled

o SA4700-104APO Intelligent Input/Output Module (Twin), alarm current changed to 7mA

o 45681-333APO mapped correct feature to XP95 VID Base (Red Flash) – Isolating

o Fixed device quantity refresh issue

o Fixed device icon spacing issue

 

v3.06 15/09/2023

What’s New:

o Automatic Online Update Functionality

o Application will periodically check for available updates & notify the user if an update is available

o This will allow Apollo to push more frequent updates

New Product Additions

o 55000-982APO – Addressable Door Retainer – 200N

o SA5500-500APO – Intelligent Open-Area VAD – Red Body (White-Flash)

o SA5500-501APO – Intelligent Open-Area VAD – Red Body (Red-Flash)

o 58000-701APO – Discovery Multi-Sensor Detector (EN54-29)

New Panel Additions

o Advanced Go

o Advanced Go+

o Taktis (EN)

Product Catalogue

o Part numbers now display with their suffix such as ‘APO’ or ‘MAR’, to match sales order part numbers

Loop Calculation Report

o Added application version number to footer to help diagnose calculation changes across different applications

Panel Location Naming

o User can now add a custom name or location to a panel added to a project, via the panel properties pane. Helps the user to identify which panel is which in large multi-panel projects, where each panel is likely the same model number.

Cable Settings

o Default cable size now set to 1.5mm, instead of the minimum value in the list based on user feedback

Properties Pane

o Properties pane title now changes to ‘Panel’/’Loop/’Product’ based on what is currently selected, to help the user identify the properties currently being presented. This improves UX for similar lists such as global panel properties vs. individual loop properties

o Only relevant properties will display, based on the products added to the design e.g. if no AV products are added, AV properties will not display

Help Menu

o Added how-to video link

  • Windows x64-bit Install Wizard support

Bug Fixes:

Product Catalogue

o 58000-600APO – Discovery Marine Optical Smoke Detector

  • Added non-SIL2 version that was missing

o 45681-524 – Discovery UL Sounder

  • Description updated to UL certification

o 45681-709 XP95 VAD Base Cat. O (White-Flash) – Isolating

  • Corrected product features to show beacon only. Was incorrectly showing sounder properties.

o Increase Part Number Character Length to prevent cut-off in some cases

Panel Catalogue

o Corrected Haes Technologies Ltd. Company name

Favourites Menu

o Favourites added are now retained after application re-launch

  • Cancel button text no longer cut-off in Dutch language
  • Algorithm Calculation improvements

o Improved how bases are ordered in the calculation, for improved accuracy

o Improved how remote LEDs are ordered in the calculation, for improved accuracy