Apollo Fire Detectors | Discovery Multi-Sensor Detector (Optical/Heat)

Discovery Multi-Sensor Detector (Optical/Heat)

58000-700APO

The Discovery Multi-Sensor Detector consists of optical smoke and thermistor temperature sensors which give a combined signal for improved false alarm management.

  • Reliable fire detection in areas with a very wide temperature range from -40°C to +70°C
  • Five operating modes for customised fire detection and enhanced false alarm management
  • Drift compensation to ensure constant sensitivity
  • A great alternative to Ionisation detectors
Technical specification
General
Warranty

10 year

Applications

Bedrooms

Hospitals

Hotels

Medium to large buildings

Offices

University campuses

Clean rooms

Warehouses

B&Bs/guest houses

Cafes

Care homes

HMOs

Restaurants

Small to medium buildings

Fire Type

Fast and slow burning fires

Wireless

No

Performance
Heat classification

A1R

Analogue value nominal

23

Analogue value (- tolerance)
0
Analogue value (+ tolerance)

4

Analogue value

23 +4/-0

Alarm level analogue value

55

Chamber type

Chevron

Mechanical
Colour

White

Sensor configuration

Horizontal optical bench housing infra-red emitter and sensor, arranged radially to detect forward scattered light.

Weight

105g

Materials housing

Polycarbonate

Materials terminals

Nickel plated stainless steel

Product diameter

100mm

Detection principle

Photo-electric light scattering.

Temperature sensitive resistance.

Product diameter

3.94in

Product height (wo/base)

50mm

Conformance
Standards

EN 54-5

EN 54-7

Approvals

FG

SBSC

BOSEC

LPCB

VdS

CPR

Electrical
Protocol voltage

5 to 9V peak to peak

Protocol voltage (max)

9V

Protocol voltage (min)

5V

Power-up surge current

1mA

Maximum power-up time

10 seconds

Status indicator – Alarm

Red

Quiescent current

470μA

Quiescent current tested at

24V dc

Supply voltage (max)

28V dc

Supply voltage (min)

17V dc

Supply voltage (Vmin-Vmax)

17 to 28V dc

Terminal functions L2

+L2 Loop in & out positive

Terminal functions L1 in

+L1 in

Terminal functions L1 out

+L1 out

Polarity

L1 & L2 are polarity insensitive

Environmental
Humidity (max)

0% RH

Humidity (min)

95% RH

Humidity Note

no condensation or icing

Humidity

95% to 0% (no condensation or icing)

Operating temperature

-40 to 70°C

Operating temperature (max)

70°C

Operating temperature (min)

-40°C

IP rating Value

IP44

Operating temperature (min)

-40°F

Operating temperature (max)

158°F

Operating temperature

-40 to 158°F