The VXB ceiling VAD beacons provide the visual notification that is required to facilitate evacuation in loud environments and for the hard of hearing.
Designed for use in conventional fire alarm systems, the ceiling versions create a cylinder of light below the device.
Available in white or red body colours alongside white and red flash options for ceiling mounting via a unique twist and lock bayonet system.
Part No.
512-201
Audible Signal
None
Visual Signal
White Flash
Voltage
18-30
Base
Shallow
Mounting
Ceiling Only
Ingress Protection
IP21C
Temp. Range (°C)
-20 to +70
Colour (Body)
White
Material
ABS
Weight (kg)
0.22
Part No.
512-202
Audible Signal
None
Visual Signal
White Flash
Voltage
18-30
Base
Deep
Mounting
Ceiling Only
Ingress Protection
IP33C & IP65
Temp. Range (°C)
-20 to +70
Colour (Body)
White
Material
ABS
Weight (kg)
0.25
Part No.
512-203
Audible Signal
None
Visual Signal
Red Flash
Voltage
18-30
Base
Shallow
Mounting
Ceiling Only
Ingress Protection
IP21C
Temp. Range (°C)
-20 to +70
Colour (Body)
White
Material
ABS
Weight (kg)
0.22
Part No.
512-204
Audible Signal
None
Visual Signal
Red Flash
Voltage
18-30
Base
Deep
Mounting
Ceiling Only
Ingress Protection
IP33C & IP65
Temp. Range (°C)
-20 to +70
Colour (Body)
White
Material
ABS
Weight (kg)
0.25
Part No.
512-205
Audible Signal
None
Visual Signal
Red Flash
Voltage
18-30
Base
Shallow
Mounting
Ceiling Only
Ingress Protection
IP21C
Temp. Range (°C)
-20 to +70
Colour (Body)
Red
Material
ABS
Weight (kg)
0.22
Part No.
512-206
Audible Signal
None
Visual Signal
Red Flash
Voltage
18-30
Base
Deep
Mounting
Ceiling Only
Ingress Protection
IP33C & IP65
Temp. Range (°C)
-20 to +70
Colour (Body)
Red
Material
ABS
Weight (kg)
0.25
Part No.
512-207
Audible Signal
None
Visual Signal
White Flash
Voltage
18-30
Base
Shallow
Mounting
Ceiling Only
Ingress Protection
IP21C
Temp. Range (°C)
-20 to +70
Colour (Body)
Red
Material
ABS
Weight (kg)
0.22
Part No.
512-208
Audible Signal
None
Visual Signal
White Flash
Voltage
18-30
Base
Deep
Mounting
Ceiling Only
Ingress Protection
IP33C & IP65
Temp. Range (°C)
-20 to +70
Colour (Body)
Red
Material
ABS
Weight (kg)
0.25
| Part No. | Audible Signal | Visual Signal | Voltage | Base | Mounting | Ingress Protection | Temp. Range (°C) | Colour (Body) | Material | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| 512-201 | None | White Flash | 18-30 | Shallow | Ceiling Only | IP21C | -20 to +70 | White | ABS | 0.22 |
| 512-202 | None | White Flash | 18-30 | Deep | Ceiling Only | IP33C & IP65 | -20 to +70 | White | ABS | 0.25 |
| 512-203 | None | Red Flash | 18-30 | Shallow | Ceiling Only | IP21C | -20 to +70 | White | ABS | 0.22 |
| 512-204 | None | Red Flash | 18-30 | Deep | Ceiling Only | IP33C & IP65 | -20 to +70 | White | ABS | 0.25 |
| 512-205 | None | Red Flash | 18-30 | Shallow | Ceiling Only | IP21C | -20 to +70 | Red | ABS | 0.22 |
| 512-206 | None | Red Flash | 18-30 | Deep | Ceiling Only | IP33C & IP65 | -20 to +70 | Red | ABS | 0.25 |
| 512-207 | None | White Flash | 18-30 | Shallow | Ceiling Only | IP21C | -20 to +70 | Red | ABS | 0.22 |
| 512-208 | None | White Flash | 18-30 | Deep | Ceiling Only | IP33C & IP65 | -20 to +70 | Red | ABS | 0.25 |
‘FIRE’ Label
116-143
BS 5839-1 and other standards require visual signals that form part of the fire system to be clearly distinguishable from other signals.
A label, that is legible when stood on the floor, with the word ‘FIRE’ is often used to distinguish visual alarms. The Cranford base labels fit the VTG, VXB and VTB products via the same mounting screws as the main product.
Mains Base
510-120 (Red)
510-121 (White)
The 24VDC VTG, VXB and VTB products can be fitted to a deep ‘mains base’ variant that includes a transformer to allow for direct installation in 110VAC and 230VAC systems.
How to Buy