VTB-32EVAD – EN54-3 & EN54-23 Approved Visual Alarm Device (Ceiling Sounder/VADs)

The VTB EN54-3 & EN54-23 approved Sounder/VADs are designed for use with conventional fire alarm systems.

The VAD and sounder functions are fully synchronised in one device that can be used without the sounder function. Sounder function and output level are configured during install.

Available in white or red body colours alongside white and red flash options for ceiling mounting via a unique twist and lock bayonet system.

Features
  • One device approved to EN54-3 (as an alarm sounder) & EN54-23 (as a visual alarm device)
  • Can be installed as VAD only with sound ‘on/off’ selection switch
  • Red flash (C-3-7) and white flash (C-3-8) options with selectable 1Hz & 0.5Hz flash rates
  • Widest range of sound adjustment on the market and 32 selectable tones
  • Shallow base IP21C for indoor applications, deep base IP33C & IP65 for surface wiring and outdoor applications
Specification & Part Numbers

Specification & Part Numbers

Part No.

511-201

Audible Signal

Siren

Visual Signal

White Flash

Voltage

18-30

Base

Shallow

Mounting

Ceiling Only

Ingress Protection

IP21C

Temp. Range (°C)

-20 to +70

Colour (Body)

White

Material

ABS

Weight (kg)

0.22

Part No.

511-202

Audible Signal

Siren

Visual Signal

White Flash

Voltage

18-30

Base

Deep

Mounting

Ceiling Only

Ingress Protection

IP33C & IP65

Temp. Range (°C)

-20 to +70

Colour (Body)

White

Material

ABS

Weight (kg)

0.25

Part No.

511-203

Audible Signal

Siren

Visual Signal

Red Flash

Voltage

18-30

Base

Shallow

Mounting

Ceiling Only

Ingress Protection

IP21C

Temp. Range (°C)

-20 to +70

Colour (Body)

White

Material

ABS

Weight (kg)

0.22

Part No.

511-204

Audible Signal

Siren

Visual Signal

Red Flash

Voltage

18-30

Base

Deep

Mounting

Ceiling Only

Ingress Protection

IP33C & IP65

Temp. Range (°C)

-20 to +70

Colour (Body)

White

Material

ABS

Weight (kg)

0.25

Part No.

511-205

Audible Signal

Siren

Visual Signal

Red Flash

Voltage

18-30

Base

Shallow

Mounting

Ceiling Only

Ingress Protection

IP21C

Temp. Range (°C)

-20 to +70

Colour (Body)

Red

Material

ABS

Weight (kg)

0.22

Part No.

511-206

Audible Signal

Siren

Visual Signal

Red Flash

Voltage

18-30

Base

Deep

Mounting

Ceiling Only

Ingress Protection

IP33C & IP65

Temp. Range (°C)

-20 to +70

Colour (Body)

Red

Material

ABS

Weight (kg)

0.25

Part No.

511-207

Audible Signal

Siren

Visual Signal

White Flash

Voltage

18-30

Base

Shallow

Mounting

Ceiling Only

Ingress Protection

IP21C

Temp. Range (°C)

-20 to +70

Colour (Body)

Red

Material

ABS

Weight (kg)

0.22

Part No.

511-208

Audible Signal

Siren

Visual Signal

White Flash

Voltage

18-30

Base

Deep

Mounting

Ceiling Only

Ingress Protection

IP33C & IP65

Temp. Range (°C)

-20 to +70

Colour (Body)

Red

Material

ABS

Weight (kg)

0.25

Part No. Audible Signal Visual Signal Voltage Base Mounting Ingress Protection Temp. Range (°C) Colour (Body) Material Weight (kg)
511-201 Siren White Flash 18-30 Shallow Ceiling Only IP21C -20 to +70 White ABS 0.22
511-202 Siren White Flash 18-30 Deep Ceiling Only IP33C & IP65 -20 to +70 White ABS 0.25
511-203 Siren Red Flash 18-30 Shallow Ceiling Only IP21C -20 to +70 White ABS 0.22
511-204 Siren Red Flash 18-30 Deep Ceiling Only IP33C & IP65 -20 to +70 White ABS 0.25
511-205 Siren Red Flash 18-30 Shallow Ceiling Only IP21C -20 to +70 Red ABS 0.22
511-206 Siren Red Flash 18-30 Deep Ceiling Only IP33C & IP65 -20 to +70 Red ABS 0.25
511-207 Siren White Flash 18-30 Shallow Ceiling Only IP21C -20 to +70 Red ABS 0.22
511-208 Siren White Flash 18-30 Deep Ceiling Only IP33C & IP65 -20 to +70 Red ABS 0.25
Sounder Performance

Sound Output, Typical (dBA) - High

98

Sound Output, Typical (dBA) - Low

66

Max Current Consumption - High

40

Max Current Consumption - Low

25

No. of Tones

32

Operating Frequency (Hz)

440 – 2900

Sound Output, Typical (dBA) Max Current Consumption No. of Tones Operating Frequency (Hz)
High Low High Low
98 66 40 25 32 440 – 2900
Diagram
Accessories
116-143 – ‘FIRE’ Label

Name

‘FIRE’ Label

Part Number

116-143

Description

BS 5839-1 and other standards require visual signals that form part of the fire system to be clearly distinguishable from other signals.

A label, that is legible when stood on the floor, with the word ‘FIRE’ is often used to distinguish visual alarms. The Cranford base labels fit the VTG, VXB and VTB products via the same mounting screws as the main product.

510-120 (Red), 510-121 (White) – Mains Base

Name

Mains Base

Part Numbers

510-120 (Red)

510-121 (White)

Description

The 24VDC VTG, VXB and VTB products can be fitted to a deep ‘mains base’ variant that includes a transformer to allow for direct installation in 110VAC and 230VAC systems.

Downloads
Compatible panels

Compatible panels

We partner with panel manufacturers around the globe.

Training and Support

Training and Support

Designed especially for you by our in-house expert team.